{"id":1104,"date":"2021-07-22T09:46:00","date_gmt":"2021-07-22T08:46:00","guid":{"rendered":"https:\/\/bestdealtv.co.uk\/?post_type=news&#038;p=1104"},"modified":"2026-03-09T14:59:50","modified_gmt":"2026-03-09T14:59:50","slug":"comprendre-a-c-z-ponderations-des-frequences-de-bruit","status":"publish","type":"news","link":"https:\/\/pulsarinstruments.com\/fr\/news\/understanding-a-c-z-noise-frequency-weightings\/","title":{"rendered":"Pond\u00e9rations de fr\u00e9quence A, C et Z : Quelle est la diff\u00e9rence ?"},"content":{"rendered":"<p class=\"wp-block-paragraph\">Comprendre les pond\u00e9rations A-C-Z des fr\u00e9quences de bruit et les diff\u00e9rences entre elles est l'une des choses les plus importantes \u00e0 conna\u00eetre pour mesurer le son. <span style=\"box-sizing: border-box; margin: 0px; padding: 0px;\">En effet, si vous choisissez une mauvaise pond\u00e9ration pour votre sonom\u00e8tre, vos r\u00e9sultats risquent de ne plus correspondre \u00e0 l'objectif et au but recherch\u00e9,<\/span> au pire, non valide (non conforme \u00e0 la loi).&nbsp;<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Vous avez peut-\u00eatre remarqu\u00e9 que certains sonom\u00e8tres vous permettent de choisir la pond\u00e9ration de fr\u00e9quence \u00e0 laquelle vous souhaitez mesurer le bruit. Les trois pond\u00e9rations en d\u00e9cibels les plus couramment utilis\u00e9es sont \"A\", \"C\" et \"Z\", telles que d\u00e9finies dans les normes des sonom\u00e8tres IEC 61672:2013 (BS EN 61672-1:2013), mais laquelle choisir ? Nous expliquons cela plus en d\u00e9tail ci-dessous, mais si vous poss\u00e9dez l'un de nos <a href=\"https:\/\/pulsarinstruments.com\/fr\/produits\/c\/sonometres\/\">Sonom\u00e8tres Nova<\/a> qui <strong>mesure toutes ces fr\u00e9quences simultan\u00e9ment<\/strong>Vous n'avez donc pas \u00e0 vous soucier de choisir une mauvaise pond\u00e9ration.\u00a0<\/p>\n\n\n\n<h2 class=\"wp-block-heading\">Explication de la pond\u00e9ration A (dB(A))<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">Pond\u00e9ration d'un sonom\u00e8tre qui rend ses relev\u00e9s conformes \u00e0 une r\u00e9ponse auditive humaine th\u00e9orique. Elle est d\u00e9finie dans diverses normes internationales telles que la norme IEC 61672, ainsi que dans diverses normes nationales telles que la norme ANSI S1.4 (\u00c9tats-Unis). La pond\u00e9ration \u2018A\u2019 est la plus couramment utilis\u00e9e et couvre toute la gamme de fr\u00e9quences de 20 Hz jusqu'\u00e0 la haute fr\u00e9quence de 20 kHz. L'oreille humaine est plus sensible aux fr\u00e9quences sonores comprises entre 500 Hz et 6 kHz (en particulier autour de 4 kHz), alors qu'elle n'est pas tr\u00e8s sensible aux fr\u00e9quences plus basses et plus \u00e9lev\u00e9es. La pond\u00e9ration \u2018A\u2019 ajuste les relev\u00e9s de niveau de pression acoustique afin de refl\u00e9ter la sensibilit\u00e9 de l'oreille humaine et est donc obligatoire dans le monde entier pour les mesures de risque de l\u00e9sions auditives. Tout sonom\u00e8tre homologu\u00e9 conforme \u00e0 la norme IEC 61672 doit comporter au moins un filtre de pond\u00e9ration A. Les mesures sont g\u00e9n\u00e9ralement affich\u00e9es en dB(A) ou dBA ou en LAeq, LAFmax, LAE.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\">Explication de la pond\u00e9ration C (dB(C))<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">La fr\u00e9quence pond\u00e9r\u00e9e C tient davantage compte de l'effet des sons de basse fr\u00e9quence sur l'oreille humaine que la pond\u00e9ration A. Elle est essentiellement plate ou lin\u00e9aire entre 31,5 Hz et 8 kHz, les deux points de 3 dB ou de \u2018demi-puissance\u2019. Les mesures de la pression acoustique de cr\u00eate sont effectu\u00e9es \u00e0 l'aide de la pond\u00e9ration de la fr\u00e9quence C. Ce pic pond\u00e9r\u00e9 C sert \u00e0 mesurer le bruit impulsionnel et est appel\u00e9 CPeak . Les mesures sont g\u00e9n\u00e9ralement affich\u00e9es en dB(C) ou dBC. Ou par exemple LCeq, LCPeak, LCE - o\u00f9 le C indique la pond\u00e9ration C.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\">Explication de la pond\u00e9ration Z (dB(Z))<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">La pond\u00e9ration Z est la r\u00e9ponse en fr\u00e9quence plate de 8Hz \u00e0 20kHz (+\/- 1,5dB), c'est le bruit r\u00e9el qui est produit sans aucune pond\u00e9ration pour l'oreille humaine (Z pour z\u00e9ro).  Souvent utilis\u00e9 dans l'analyse des bandes d'octave et pour d\u00e9terminer le bruit ambiant. Les mesures effectu\u00e9es sont affich\u00e9es en tant que dB(Z) ou dBZ, ou LZeq, LZFmax, LZE - o\u00f9 le Z indique l'utilisation de la pond\u00e9ration Z.\u00a0<\/p>\n\n\n\n<h2 class=\"wp-block-heading\">Pond\u00e9ration A vs C vs Z (comparaison rapide)<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">La norme relative aux sonom\u00e8tres IEC 61672 sp\u00e9cifie les performances et les tol\u00e9rances des courbes de pond\u00e9ration des fr\u00e9quences \u00e0 utiliser.<\/p>\n\n\n\n<figure class=\"wp-block-table\"><table><tbody><tr><td><strong>Fr\u00e9quence (Hz)<\/strong><\/td><td><strong>63<\/strong><\/td><td><strong>125<\/strong><\/td><td><strong>250<\/strong><\/td><td><strong>500<\/strong><\/td><td><strong>1k<\/strong><\/td><td><strong>2k<\/strong><\/td><td><strong>4k<\/strong><\/td><td><strong>8k<\/strong><\/td><td><strong>16k<\/strong><\/td><\/tr><tr><td>Pond\u00e9ration A (dB)<\/td><td>- 26.2<\/td><td>- 16.1<\/td><td>- 8.6<\/td><td>- 3.2<\/td><td>0<\/td><td>1.2<\/td><td>1<\/td><td>-1.1<\/td><td>- 6.6<\/td><\/tr><tr><td>Pond\u00e9ration C (dB)<\/td><td>- 0.8<\/td><td>- 0.2<\/td><td>0<\/td><td>0<\/td><td>0<\/td><td>- 0.2<\/td><td>- 0.8<\/td><td>- 3.0<\/td><td>- 8.5<\/td><\/tr><tr><td>Pond\u00e9ration Z (dB)<\/td><td>0<\/td><td>0<\/td><td>0<\/td><td>0<\/td><td>0<\/td><td>0<\/td><td>0<\/td><td>0<\/td><td>0<\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n<h2 class=\"wp-block-heading\">Quelle pond\u00e9ration utiliser ?<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">L'oreille humaine est plus sensible aux fr\u00e9quences sonores comprises entre 500 Hz et 6 kHz. Lorsque l'on mesure les variations du niveau de pression acoustique, en particulier pour les niveaux sonores potentiellement dommageables sur le lieu de travail, il est important que le sonom\u00e8tre puisse donner une repr\u00e9sentation pr\u00e9cise de ce que l'oreille humaine entend r\u00e9ellement. Les pond\u00e9rations fr\u00e9quentielles permettent de donner plus de poids \u00e0 certaines fr\u00e9quences qu'\u00e0 d'autres (c'est-\u00e0-dire en accentuant certaines fr\u00e9quences et en en att\u00e9nuant d'autres).&nbsp;<\/p>\n\n\n\n<h3 class=\"wp-block-heading\">Pond\u00e9ration A pour le bruit au travail<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">Lorsqu'il s'agit de mesurer l'impact des <strong>le bruit au travail lors de l'audition des mesures de bruit pond\u00e9r\u00e9es A<\/strong> doit \u00eatre pr\u00e9sent\u00e9 (couramment affich\u00e9 en dB(A), (correctement \u00e9crit en LAeq)). Des relev\u00e9s repr\u00e9sentatifs du niveau sonore moyen pond\u00e9r\u00e9 \u2018A\u2019 doivent \u00eatre effectu\u00e9s pour chaque t\u00e2che entreprise par un employ\u00e9, puis, \u00e0 l'aide d'un logiciel ou de la calculatrice du HSE, le niveau d'exposition d'un individu doit \u00eatre d\u00e9termin\u00e9.\u00a0<\/p>\n\n\n\n<h3 class=\"wp-block-heading\">Pond\u00e9ration C pour mesurer le bruit impulsionnel<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">Les gens oublient souvent qu'il est n\u00e9cessaire d'\u00e9valuer le risque li\u00e9 \u00e0 tout bruit impulsif (bruits tr\u00e8s soudains et de courte dur\u00e9e, coups et chocs). La pond\u00e9ration C est utilis\u00e9e pour obtenir la pression acoustique de cr\u00eate du bruit impulsif auquel l'oreille humaine est expos\u00e9e dB(C) (ou LCPeak).&nbsp;<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">La plupart des sonom\u00e8tres modernes et des <a href=\"https:\/\/pulsarinstruments.com\/fr\/produits\/c\/dosimetres-de-bruit\/\">dosim\u00e8tres de bruit<\/a> mesure simultan\u00e9ment le LAeq et le LCpeak.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><\/p>","protected":false},"excerpt":{"rendered":"<p>Comprendre la diff\u00e9rence entre les pond\u00e9rations des fr\u00e9quences de bruit est l'une des choses les plus importantes que vous devez savoir lorsque vous mesurez le son. En effet, si vous choisissez la mauvaise pond\u00e9ration sur votre sonom\u00e8tre, vos r\u00e9sultats risquent de ne plus \u00eatre pertinents et, dans le pire des cas, d'\u00eatre invalides (non conformes \u00e0 la loi). <\/p>","protected":false},"featured_media":0,"template":"","format":"standard","news-category":[54],"class_list":["post-1104","news","type-news","status-publish","format-standard","hentry","news-category-noise-measurement"],"_links":{"self":[{"href":"https:\/\/pulsarinstruments.com\/fr\/wp-json\/wp\/v2\/news\/1104","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/pulsarinstruments.com\/fr\/wp-json\/wp\/v2\/news"}],"about":[{"href":"https:\/\/pulsarinstruments.com\/fr\/wp-json\/wp\/v2\/types\/news"}],"version-history":[{"count":2,"href":"https:\/\/pulsarinstruments.com\/fr\/wp-json\/wp\/v2\/news\/1104\/revisions"}],"predecessor-version":[{"id":21761,"href":"https:\/\/pulsarinstruments.com\/fr\/wp-json\/wp\/v2\/news\/1104\/revisions\/21761"}],"wp:attachment":[{"href":"https:\/\/pulsarinstruments.com\/fr\/wp-json\/wp\/v2\/media?parent=1104"}],"wp:term":[{"taxonomy":"news-category","embeddable":true,"href":"https:\/\/pulsarinstruments.com\/fr\/wp-json\/wp\/v2\/news-category?post=1104"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}