NoisePen Personal Sound Exposure Meter zoom

Hover

NoisePen Personal Sound Exposure Meter zoom

Hover

NoisePen Personal Sound Exposure Meter zoom

Hover

NoisePen Personal Sound Exposure Meter zoom

Hover

NoisePen Personal Sound Exposure Meter
NoisePen Personal Sound Exposure Meter
NoisePen Personal Sound Exposure Meter
NoisePen Personal Sound Exposure Meter
Full Screen

NoisePen Personal Sound Exposure Meter

(1 customer review)

From: £499.00 (Ex. VAT/GST)

Monitoring your employees Personal Sound Exposure has never been easier. Capture, record and calculate workers’ noise exposure with Pulsar’s innovative NoisePen Dosemeter – a Personal Sound Exposure Meter (PSEM) that is designed to make your job easier.

  • 30 hours battery life – start your recording with peace of mind knowing the battery will last multiple shifts.
  • Easy to use – there are no buttons, screens, or cables meaning employees are unable to tamper with the device.
  • Schedule your recordings – you can fit your NoisePen to your employees at the start of a shift and have the recording start/finish whenever you like.
  • Covers all essential Noise at Work parameters – such as LAeq, LEP,d, % Dose and TWA for compliance with occupational noise regulations
  • Meets industry standards – meets IEC 61252:1993 and ANSI S1.25:1991 standards
  • No additional reader of charger needed – This NoisePen comes with everything you need to complete your measurements
  • Free software included – Easily complete your report with our free AnalyzerPlus software
Category:

From: £499.00 (Ex. VAT/GST)

Website prices are in GBP. You can change currency in the cart or checkout before purchase.

NoisePen Quantity

Select how many NoisePens you'd like.

£499.00 (Ex. VAT/GST) each

Protective Carrying Cases

We understand that over time, the carrying cases supplied with your Pulsar equipment can become worn or damaged. That’s why our protective cases are available to purchase individually.

  • Protect your instruments from accidental damage, dust, and water ingress
  • Keep equipment secure with specially designed foam cut-outs
  • Lightweight yet durable

Acoustic Calibrator

  • Delivery Time | 2-3 days
  • Warranty | Extended 7-year warranty
  • Calibration | 12-months
  • Software | License-free software included
  • Shipping | Worldwide

We accept the following payments:

Payments accepted

Description

The NoisePen Personal Sound Exposure Meter has no cables, displays or controls, and needs no separate charger or reader unit, making it simple to use and the perfect solution for monitoring Noise at Work over a whole working day or week especially for shift workers, lone workers, confined-space workers and people working in remote areas. The NoisePen noise dosemeter is fully compliant with noise at work health and safety measurement standards around the world.

This great value, self-contained personal noise dosemeter can capture, record and calculate noise exposure data for a period of time over 30 hours. The NoisePen measures all the noise parameters you need for legally compliant occupational noise monitoring. This PSEM is a self-contained noise monitor ideally suited for workers ‘on the go’; it has no cables, displays or controls and several different mounting options are available.

The NoisePen does not require an additional Charger or Reader Unit – all interactions are done via USB to a PC and our outstanding powerful analysis and reporting software, Pulsar AnalyzerPlus:

  • All noise measurement programming and key functions such as start-stop, set up and configuration of the device, download, view and store measurements are performed before or on completion of field measurements.
  • Calibration of the NoisePen is also undertaken before taking a measurement with an acoustic calibrator and verified and logged via the software.  The same process is carried out on return of the unit to your office.
  • Schedule a timed measurement at a date and time of your choice. You can also repeat a selected measurement pattern over a period of 7 days without having to reset the NoisePen.
  • Get a full map of Time History information to help you determine when key noise problems occur during a worker’s day.
  • View all the essential data you need such LAeq, LEP,d, % Dose and TWA for compliance with occupational noise regulations
  • The additional ‘C’ frequency weighted peak Time History allows you to fully assess risks from impulsive noise in the workplace.

NOTE: an acoustic calibrator is required for the field calibration and activation of the NoisePen. You can choose to add one above.

The NoisePen can be purchased on its own or as a complete kit that includes the dosimeter, an acoustic calibrator, and a carrying case.

 

NoisePen

  • NoisePen Personal Sound Exposure Meter
  • Windshield
  • Leather Shoulder Strap
  • Calibration certificates
  • USB download cable
  • AnalyzerPlus noise analysis software

 

NoisePen Kit

Our NoisePen kits include all the essential accessories supplied in a carrying case.

  • NoisePen Personal Sound Exposure Meter
  • Acoustic Calibrator
  • Windshield
  • Carrying case
  • Leather Shoulder Strap
  • Calibration certificates
  • USB download cable
  • AnalyzerPlus noise analysis software

 

The NoisePen Personal Sound Exposure Meter and Acoustic Calibrator include a standard 1-year warranty, which can be extended to 7 years when the instruments are returned to Pulsar Instruments for annual calibration.

The sections below outline the basic operation of the NoisePen Noise Dosimeter. For full instructions, please refer to the user manual.

 

Charging the NoisePen

Fully charge the NoisePen before use using the supplied USB cable. The LED glows red while charging and turns blue when fully charged. A full charge typically takes less than four hours and provides up to 24 hours of operation.

 

Connecting to AnalyzerPlus

Plug the NoisePen into a PC with our licence-free AnalyzerPlus software installed. The software automatically detects the device and opens the NoisePen window. From here, you can configure the NoisePen, synchronise the clock and schedule measurements.

 

Calibrating the NoisePen

Before and after each measurement, remove the windshield and fit an acoustic calibrator (94 dB or 114 dB) to the microphone. Switch on the calibrator and select Calibrate in AnalyzerPlus. The result and any offset from the last factory calibration are logged automatically. When calibration is complete, switch off the calibrator and replace the windshield.

 

Starting a Measurement

To start a manual measurement, connect the NoisePen to AnalyzerPlus, perform a calibration, then select Start. Remove the calibrator, replace the windshield and disconnect the NoisePen. The LED flashes blue to show that it is recording.

 

Wearing the NoisePen

Attach the NoisePen to the shoulder using the supplied leather strap, keeping the microphone within 10 cm of the ear. The device automatically records noise exposure throughout the shift, with no on-device controls.

 

Stopping and Downloading Data

At the end of the shift, reconnect the NoisePen to AnalyzerPlus and select Stop. Perform a post-measurement calibration, then download the data. Results can be sorted, reviewed, and reports generated directly in AnalyzerPlus, or data can be exported for further analysis.

 

Scheduled Measurements

You can set the NoisePen to start and stop measurements automatically at chosen times. Up to 12 schedules can be created up to 28 days in advance. To set a schedule, connect the NoisePen to AnalyzerPlus and open the Configure menu. Under the Controls tab, select Enable Schedules and then New Schedule. Set the required start times and days, then choose Save to Instrument. Once disconnected, the NoisePen will begin measuring at the scheduled time. Schedules can be enabled, disabled or cleared from the same window.

The NoisePen Noise Dosimeter is a compact personal sound exposure meter for measuring personal noise exposure over a working day or shift. It captures all key parameters, including LAeq, LEP,d, % Dose, and TWA, to give a clear picture of an individual’s noise exposure. With no screens, cables, or buttons, the NoisePen is simple to use and less likely to be interfered with during use. It’s comfortable to wear on the shoulder or upper arm, making it ideal for accurate occupational noise measurements across a wide range of workplaces.

 

Workplace Noise Monitoring

The NoisePen is ideal for measuring individual noise exposure in busy workplaces where people move between tasks or operate noisy machinery. It allows Health and Safety teams to monitor employees throughout their shift without supervision, making it especially useful where it is unsafe or impractical to take measurements with a handheld sound level meter. The device is worn on the shoulder or upper arm and runs automatically once configured in our licence-free AnalyzerPlus software. After monitoring, results can be downloaded to create clear reports for workplace noise assessments.

 

Hospitality Noise & Entertainment Noise

The NoisePen Noise Dosimeter is ideal for monitoring noise exposure in venues where music and crowd noise change throughout the day. It provides reliable measurements without supervision, making it ideal for bars, nightclubs, theatres, and live events. Since it runs automatically once set up in our licence-free AnalyzerPlus software, staff can wear it comfortably during their shift without disruption. Once monitoring is complete, results can be reviewed to help protect employees and comply with workplace noise regulations.

Accuracy
Class 2

Applicable standards
IEC 61252:1993
ANSI S1.25:1991
IEC 61000-6-1:2007(EMC)
IEC 61000-6-3:2007(EMC)

Microphone
Removable Pre-polarised Electret ½” Class 2

Measurement range
70-140dB(A)
90dB(C) to 143dB(C) Peak

Time Weightings
‘F’ (Fast), ‘S’ (Slow) or None

Frequency weightings
CH1 (Integrator): A
CH2 (Peak), C & Z

Integrators
One integrator. Set up either: UK, EU, OSHA, HC & OSHA NC, OSHA HC & ACGIH, MSHA HC & MSHA
EC or Custom

Time History data Rates
One second, one minute

Languages
English, French, German, Italian and Spanish as standard

Power/Batteries
Custom-made 1.2V Internal NiMH battery pack.
Rechargeable via USB 5V

Battery life
Over 30 hours measuring
Recharge in less than 4 hours (0% to 100%)
Weight with battery: 82gms

Size
124mm x 34mm x 28mm excl windshield

Connections
Mini-USB (supplied) to connect to PC or power supply

Operating temperature
0-40°C

Memory
Enough memory to store 20 x 8hr shifts at storage of 1s for both Peak and integrator 160hrs at 1s storage rate)

Measurement parameters
Graph of Short LAeq, LCPeak or LZPeak

Software
Pulsar AnalyzerPlus for Windows 7 and above

Warranty
12 months extendable to 7 years

Accessories
Acoustic Calibrator
Kit cases
NoisePen fixings
Mains Power Supply

Datasheet (pdf, 145KB)
English
Datasheet (pdf, 299KB)
German
Datasheet (pdf, 131KB)
French
User Manual (pdf, 588KB)
English

1 review for NoisePen Personal Sound Exposure Meter

  1. Innocent Mutambuze

    The NoisePen is very user-friendly, operating as a true plug-and-play device.

    Reviewer was offered a benefit for sharing their feedback.

Add a review

Your email address will not be published. Required fields are marked *


You may also like…

Clients trust in us to deliver quality and superior service

Pulsar Instruments are highly-recommended and trusted by our customers.

Latest news stories

Read our latest news articles here…

Pulsar Instruments Announces Two New Distributors in the Middle East

Pulsar Instruments Announces Two New Distributors in the Middle East

30th Oct 2023

As part of Pulsar Instruments’ ongoing commitment to expanding in the Middle East, we are excited to announce partnerships with two new regional distributors. After…

Read full story

Calculating Hearing Protection: 3 Easy Methods

Calculating Hearing Protection: 3 Easy Methods

21st Sep 2023

What’s involved? The selection of hearing protection for noise at work is a simple process as long as you have the right equipment and are…

Read full story

Introducing Our New Authorised Repair Centre in Australia

Introducing Our New Authorised Repair Centre in Australia

22nd May 2023

Introducing Our New Authorised Repair Centre in Australia, Expert Testing Services We at Pulsar Instruments are thrilled to bring you some exciting news! We’ve recently…

Read full story

Read all articles about Pulsar Instruments and the latest information and guidelines for noise measurement and sound control in your industry…

All news stories

We’re the noise measurement equipment
Experts
with over 50 years experience

7-Year Warranty

7-Year Warranty

We focus on customer care, providing great support, advice and assistance.

Rated 5 Stars

Rated 5 Stars

Pulsar Instruments are highly recommended and trusted by our customers.

Free UK Shipping

Free UK Shipping

Free next-day despatch on all orders placed before 12 pm.

Don’t miss out! Subscribe now…

Sign up to our newsletter to stay up-to-date with…

The latest news about Pulsar Instruments products, training days and company updates.

The latest guidelines and suggested recommendations for noise measurement and sound control.

Exclusive offers, discounts and promotions delivered directly to your inbox.

  • This field is for validation purposes and should be left unchanged.