Warranty

7-Year Warranty When Calibrated Annually

We focus on customer care, providing great support, advice and assistance.

Fast Delivery

Next-Day Despatch for In-Stock Items

Next working-day despatch for all in-stock orders placed before 12pm.

In-House Technical Support Team

Get expert help from our in-house technical support team whenever you need assistance with your equipment.

50 years in business

Over 50 Years of Expertise

Weโ€™re recognised and trusted noise measurement experts โ€“ Since 1969.

NoisePenย Personal Sound Exposure Meter

(1 customer review)

From: £510.00 (Ex. VAT/GST)

Monitoring your employees’ personal sound exposure has never been easier. Capture, record and calculate workersโ€™ noise exposure with Pulsarโ€™s innovative NoisePen Dosimeter โ€“ a Personal Sound Exposure Meter (PSEM) that is designed to make your job easier.

  • Class 2 personal sound exposure meter
  • Measures LAeq, LEP,d, LCpeak, TWA and % Dose
  • More than 30 hours of battery life
  • No buttons, screens or cables, preventing tampering
  • USB connection for simple setup and data analysis with AnalyzerPlus

From: £510.00 (Ex. VAT/GST)

Website prices are in GBP. You can change currency in the cart or checkout before purchase.

NoisePen Quantity

Select how many NoisePens you'd like.

£510.00 (Ex. VAT/GST) each

Protective Carrying Cases

We understand that over time, the carrying cases supplied with your Pulsar equipment can become worn or damaged. Thatโ€™s why our protective cases are available to purchase individually.

  • Protect your instruments from accidental damage, dust, and water ingress
  • Keep equipment secure with specially designed foam cut-outs
  • Lightweight yet durable

Acoustic Calibrator

  • Delivery Time | 2-3 days
  • Warranty | Extended 7-year warranty
  • Calibration | 12-months
  • Software | License-free software included
  • Shipping | Worldwide

We accept the following payments:

Payments accepted

Description

The NoisePen is a Class 2 personal sound exposure meter designed for monitoring an individualโ€™s daily noise exposure. Fully compliant with IEC 61252:1993 and ANSI S1.25:1991, the NoisePen captures all essential occupational noise parameters over a full working day. With no buttons, screens or cables, it cannot be adjusted or tampered with during use, ensuring reliable and accurate measurements.

 

Suitable for occupational noise exposure assessments

The NoisePen is ideal for monitoring an individualโ€™s noise exposure throughout the day, particularly where employees move between different tasks or locations. It measures all key occupational noise parameters, including LAeq,ย LEP,dย (LEX,8h),ย LCPeak,ย TWAย andย % Dose, providing the data required to assess compliance with workplace noise regulations.

 

Comfortable, wearable and built for daily use

Designed for use in real working environments, the NoisePen is lightweight and can be worn securely on the shoulder using the provided leather mounting strap. Its rechargeable battery provides more than 30 hours of measurement time, allowing it to monitor full shifts. With no external reader required, the NoisePen connects directly to a PC via USB, making it easy to set up and manage your measurements.

 

Straightforward setup and reporting with AnalyzerPlus

All configuration, scheduling, calibration and download data is completed using our licence-free AnalyzerPlus software. Measurements can be viewed, analysed and reported on, with Time History data showing how exposure varies throughout the day.

 

Flexible scheduling for extended monitoring

The NoisePen allows measurements to start and finish automatically at set times, making it ideal for workers on varying or unsupervised shifts. Measurement schedules can be programmed for up to seven days, making it easy to collect data over longer periods.

 

Other noise dosimeter models

For organisations that need a more durable personal noise dosimeter, the NoiseBadge offers a robust, shoulder-mounted alternative to the NoisePen. With a metal casing, it is ideal for industries such as construction, demolition and heavy manufacturing, where durability is essential.

For hazardous or potentially explosive atmospheres, the Intrinsically Safe NoiseBadge provides a certified solution for use in mining, petrochemical facilities and other environments where combustion risks must be carefully managed.

Both models measure the same occupational noise parameters as the NoisePen, allowing you to choose the dosimeter best suited to your working environment.

Video

Product Options

The NoisePen can be purchased on its own or as a complete kit that includes the dosimeter, an acoustic calibrator, and a carrying case.

 

NoisePen

  • NoisePen Personal Sound Exposure Meter
  • Windshield
  • Leather Shoulder Strap
  • Calibration certificates
  • USB download cable
  • AnalyzerPlus noise analysis software

 

NoisePen Kit

Our NoisePen kits include all the essential accessories supplied in a carrying case.

  • NoisePen Personal Sound Exposure Meter
  • Acoustic Calibrator
  • Windshield
  • Carrying case
  • Leather Shoulder Strap
  • Calibration certificates
  • USB download cable
  • AnalyzerPlus noise analysis software

 

The NoisePen Personal Sound Exposure Meter and Acoustic Calibrator include a standard 1-year warranty, which can be extended to 7 years when the instruments are returned to Pulsar Instruments for annualย calibration.

Instructions

The sections below outline the basic operation of the NoisePen Noise Dosimeter. For full instructions, please refer to the user manual.

 

Charging the NoisePen

Fully charge the NoisePen before use using the supplied USB cable. The LED glows red while charging and turns blue when fully charged. A full charge typically takes less than four hours and provides up to 24 hours of operation.

 

Connecting to AnalyzerPlus

Plug the NoisePen into a PC with our licence-free AnalyzerPlus software installed. The software automatically detects the device and opens the NoisePen window. From here, you can configure the NoisePen, synchronise the clock and schedule measurements.

 

Calibrating the NoisePen

Before and after each measurement, remove the windshield and fit an acoustic calibrator (94 dB or 114 dB) to the microphone. Switch on the calibrator and select Calibrate in AnalyzerPlus. The result and any offset from the last factory calibration are logged automatically. When calibration is complete, switch off the calibrator and replace the windshield.

 

Starting a Measurement

To start a manual measurement, connect the NoisePen to AnalyzerPlus, perform a calibration, then select Start. Remove the calibrator, replace the windshield and disconnect the NoisePen. The LED flashes blue to show that it is recording.

 

Wearing the NoisePen

Attach the NoisePen to the shoulder using the supplied leather strap, keeping the microphone within 10 cm of the ear. The device automatically records noise exposure throughout the shift, with no on-device controls.

 

Stopping and Downloading Data

At the end of the shift, reconnect the NoisePen to AnalyzerPlus and select Stop. Perform a post-measurement calibration, then download the data. Results can be sorted, reviewed, and reports generated directly in AnalyzerPlus, or data can be exported for further analysis.

 

Scheduled Measurements

You can set the NoisePen to start and stop measurements automatically at chosen times. Up to 12 schedules can be created up to 28 days in advance. To set a schedule, connect the NoisePen to AnalyzerPlus and open the Configure menu. Under the Controls tab, select Enable Schedules and then New Schedule. Set the required start times and days, then choose Save to Instrument. Once disconnected, the NoisePen will begin measuring at the scheduled time. Schedules can be enabled, disabled or cleared from the same window.

Applications

The NoisePen Noise Dosimeter is a compact personal sound exposure meter for measuring personal noise exposure over a working day or shift. It captures all key parameters, including LAeq, LEP,d, % Dose, and TWA, to give a clear picture of an individualโ€™s noise exposure. With no screens, cables, or buttons, the NoisePen is simple to use and less likely to be interfered with during use. Itโ€™s comfortable to wear on the shoulder or upper arm, making it ideal for accurate occupational noise measurements across a wide range of workplaces.

 

Workplace Noise Monitoring

The NoisePen is ideal for measuring individual noise exposure in busy workplaces where people move between tasks or operate noisy machinery. It allows Health and Safety teams to monitor employees throughout their shift without supervision, making it especially useful where it is unsafe or impractical to take measurements with a handheld sound level meter. The device is worn on the shoulder or upper arm and runs automatically once configured in our licence-free AnalyzerPlus software. After monitoring, results can be downloaded to create clear reports for workplace noise assessments.

 

Hospitality Noise & Entertainment Noise

The NoisePen Noise Dosimeter is ideal for monitoring noise exposure in venues where music and crowd noise change throughout the day. It provides reliable measurements without supervision, making it ideal for bars, nightclubs, theatres, and live events. Since it runs automatically once set up in our licence-free AnalyzerPlus software, staff can wear it comfortably during their shift without disruption. Once monitoring is complete, results can be reviewed to help protect employees and comply with workplace noise regulations.

Specifications

Accuracy
Class 2

Applicable standards
IEC 61252:1993
ANSI S1.25:1991
IEC 61000-6-1:2007(EMC)
IEC 61000-6-3:2007(EMC)

Microphone
Removable Pre-polarised Electret ยฝโ€ Class 2

Measurement range
70-140dB(A)
90dB(C) to 143dB(C) Peak

Time Weightings
โ€˜Fโ€™ (Fast), โ€˜Sโ€™ (Slow) or None

Frequency weightings
CH1 (Integrator): A
CH2 (Peak), C & Z

Integrators
One integrator. Set up either: UK, EU, OSHA, HC & OSHA NC, OSHA HC & ACGIH, MSHA HC & MSHA
EC or Custom

Time History data Rates
One second, one minute

Languages
English, French, German, Italian and Spanish as standard

Power/Batteries
Custom-made 1.2V Internal NiMH battery pack.
Rechargeable via USB 5V

Battery life
Over 30 hours measuring
Recharge in less than 4 hours (0% to 100%)
Weight with battery: 82gms

Size
124mm x 34mm x 28mm excl windshield

Connections
Mini-USB (supplied) to connect to PC or power supply

Operating temperature
0-40ยฐC

Memory
Enough memory to store 20 x 8hr shifts at storage of 1s for both Peak and integrator 160hrs at 1s storage rate)

Measurement parameters
Graph of Short LAeq, LCPeak or LZPeak

Software
Pulsar AnalyzerPlus for Windows 7 and above

Warranty
12 months extendable to 7 years

Accessories
Acoustic Calibrator
Kit cases
NoisePen fixings
Mains Power Supply

Downloads

Datasheet (pdf, 145KB)
English
Datasheet (pdf, 299KB)
German
Datasheet (pdf, 131KB)
French
User Manual (pdf, 588KB)
English

Reviews (1)

1 review for NoisePenย Personal Sound Exposure Meter

  1. Innocent Mutambuze

    The NoisePen is very user-friendly, operating as a true plug-and-play device.

    Reviewer was offered a benefit for sharing their feedback.

Add a review

Your email address will not be published. Required fields are marked *

Need Help?

You may also like…

Clients trust in us to deliver quality and superior service

Over 50 years of delivering accurate, reliable noise and vibration measurement equipment

Pulsar Nova Customers

Latest news stories

Read our latest news articles here…

Pulsar Instruments Announces Two New Distributors in the Middle East

Pulsar Instruments Announces Two New Distributors in the Middle East

30th Oct 2023

As part of Pulsar Instruments’ ongoing commitment to expanding in the Middle East, we are excited to announce partnerships with two new regional distributors. After…

Read full story

Calculating Hearing Protection: 3 Easy Methods

Calculating Hearing Protection: 3 Easy Methods

21st Sep 2023

Whatโ€™s involved? The selection of hearing protection for noise at work is a simple process as long as you have the right equipment and are…

Read full story

Introducing Our New Authorised Repair Centre in Australia

Introducing Our New Authorised Repair Centre in Australia

22nd May 2023

Introducing Our New Authorised Repair Centre in Australia, Expert Testing Services We at Pulsar Instruments are thrilled to bring you some exciting news! We’ve recently…

Read full story

Read all articles about Pulsar Instruments and the latest information and guidelines for noise measurement and sound control in your industryโ€ฆ

All news stories

We’re the noise measurement equipment
Experts
with over 50 years experience

7-Year Warranty When Calibrated Annually

7-Year Warranty When Calibrated Annually

We focus on customer care, providing great support, advice and assistance.

Next-Day Despatch for In-Stock Items

Next-Day Despatch for In-Stock Items

Next working-day despatch for all in-stock orders placed before 12pm.

In-House Technical Support Team

In-House Technical Support Team

Get expert help from our in-house technical support team whenever you need assistance with your equipment.

Donโ€™t miss out! Subscribe now…

Sign up to our newsletter to stay up-to-date withโ€ฆ

The latest news about Pulsar Instruments products, training days and company updates.

The latest guidelines and suggested recommendations for noise measurement and sound control.

Exclusive offers, discounts and promotions delivered directly to your inbox.