Warranty

10-Year Warranty on Selected Pulsar Products

Selected products include an extended 10-year warranty when calibrated annually.

Online Training with Noise Products

Access our Online Noise Awareness Course at no extra cost when you buy our noise monitoring equipment.

Licence-Free Software with Pulsar Products

Use our software without subscriptions, recurring charges or additional licence fees.

In-House Technical Support Team

Get expert help from our in-house technical support team whenever you need assistance with your equipment.

NoisePen Personal Noise Dosimeter

(1 customer review)

Price range: £510.00 through £2,970.00 (Ex. VAT/GST)

Monitoring your employees’ personal sound exposure has never been easier. Capture, record and calculate workers’ noise exposure with Pulsar’s innovative NoisePen Dosimeter.

  • Class 2 personal noise dosimeter
  • Measures LAeq, LEP,d, LCpeak, TWA and % Dose
  • More than 30 hours of battery life
  • No buttons, screens or cables, preventing tampering
  • USB connection for simple setup and data analysis with AnalyzerPlus
SKU: N/A Category: Brand:

Price range: £510.00 through £2,970.00 (Ex. VAT/GST)

  • Delivery Time | 2-3 days
  • Shipping | Worldwide
  • Warranty | Extended 10-year warranty
  • Software | License-free software included
  • Training | Online Noise Awareness course

We accept the following payments:

Payments accepted

Description

The NoisePen is a Class 2 noise dosimeter designed for monitoring an individual’s daily noise exposure. Fully compliant with IEC 61252:1993 and ANSI S1.25:1991, the NoisePen captures all essential occupational noise parameters over a full working day. With no buttons, screens or cables, it cannot be adjusted or tampered with during use, ensuring reliable and accurate measurements.

 

Suitable for occupational noise exposure assessments

The NoisePen is ideal for monitoring an individual’s noise exposure throughout the day, particularly where employees move between different tasks or locations. It measures all key occupational noise parameters, including LAeq, LEP,d (LEX,8h), LCPeak, TWA and % Dose, providing the data required to assess compliance with workplace noise regulations.

 

Comfortable, wearable and built for daily use

Designed for use in real working environments, the NoisePen is lightweight and can be worn securely on the shoulder using the provided leather mounting strap. Its rechargeable battery provides more than 30 hours of measurement time, allowing it to monitor full shifts. With no external reader required, the NoisePen connects directly to a PC via USB, making it easy to set up and manage your measurements.

 

Straightforward setup and reporting with AnalyzerPlus

All configuration, scheduling, calibration and download data is completed using our licence-free AnalyzerPlus software. Measurements can be viewed, analysed and reported on, with Time History data showing how exposure varies throughout the day.

 

Flexible scheduling for extended monitoring

The NoisePen allows measurements to start and finish automatically at set times, making it ideal for workers on varying or unsupervised shifts. Measurement schedules can be programmed for up to seven days, making it easy to collect data over longer periods.

 

Other noise dosimeter models

For organisations that need a more durable personal noise dosimeter, the NoiseBadge offers a robust, shoulder-mounted alternative to the NoisePen. With a metal casing, it is ideal for industries such as construction, demolition and heavy manufacturing, where durability is essential.

For hazardous or potentially explosive atmospheres, the Intrinsically Safe NoiseBadge provides a certified solution for use in mining, petrochemical facilities and other environments where combustion risks must be carefully managed.

Both models measure the same occupational noise parameters as the NoisePen, allowing you to choose the dosimeter best suited to your working environment.

Product Video

Product Options

The NoisePen can be purchased on its own or as a complete kit that includes the dosimeter, an acoustic calibrator, and a carrying case.

 

NoisePen

  • NoisePen Personal Noise Dosimeter
  • Windshield
  • Leather Shoulder Strap
  • Calibration certificates
  • USB download cable
  • AnalyzerPlus noise analysis software

 

NoisePen Kit

Our NoisePen kits include all the essential accessories supplied in a carrying case.

  • NoisePen Personal Noise Dosimeter
  • Acoustic Calibrator
  • Windshield
  • Carrying case
  • Leather Shoulder Strap
  • Calibration certificates
  • USB download cable
  • AnalyzerPlus noise analysis software

 

The NoisePen Personal Noise Dosimeter and Acoustic Calibrator include a standard 1-year warranty, which can be extended to 10 years when the instruments are returned to Pulsar Instruments for annual calibration.

Instructions

The sections below outline the basic operation of the NoisePen Noise Dosimeter. For full instructions, please refer to the user manual.

 

Charging the NoisePen

Fully charge the NoisePen before use using the supplied USB cable. The LED glows red while charging and turns blue when fully charged. A full charge typically takes less than four hours and provides up to 24 hours of operation.

 

Connecting to AnalyzerPlus

Plug the NoisePen into a PC with our licence-free AnalyzerPlus software installed. The software automatically detects the device and opens the NoisePen window. From here, you can configure the NoisePen, synchronise the clock and schedule measurements.

 

Calibrating the NoisePen

Before and after each measurement, remove the windshield and fit an acoustic calibrator (94 dB or 114 dB) to the microphone. Switch on the calibrator and select Calibrate in AnalyzerPlus. The result and any offset from the last factory calibration are logged automatically. When calibration is complete, switch off the calibrator and replace the windshield.

 

Starting a Measurement

To start a manual measurement, connect the NoisePen to AnalyzerPlus, perform a calibration, then select Start. Remove the calibrator, replace the windshield and disconnect the NoisePen. The LED flashes blue to show that it is recording.

 

Wearing the NoisePen

Attach the NoisePen to the shoulder using the supplied leather strap, keeping the microphone within 10 cm of the ear. The device automatically records noise exposure throughout the shift, with no on-device controls.

 

Stopping and Downloading Data

At the end of the shift, reconnect the NoisePen to AnalyzerPlus and select Stop. Perform a post-measurement calibration, then download the data. Results can be sorted, reviewed, and reports generated directly in AnalyzerPlus, or data can be exported for further analysis.

 

Scheduled Measurements

You can set the NoisePen to start and stop measurements automatically at chosen times. Up to 12 schedules can be created up to 28 days in advance. To set a schedule, connect the NoisePen to AnalyzerPlus and open the Configure menu. Under the Controls tab, select Enable Schedules and then New Schedule. Set the required start times and days, then choose Save to Instrument. Once disconnected, the NoisePen will begin measuring at the scheduled time. Schedules can be enabled, disabled or cleared from the same window.

Applications

The NoisePen Noise Dosimeter is a compact personal sound exposure meter for measuring personal noise exposure over a working day or shift. It captures all key parameters, including LAeq, LEP,d, % Dose, and TWA, to give a clear picture of an individual’s noise exposure. With no screens, cables, or buttons, the NoisePen is simple to use and less likely to be interfered with during use. It’s comfortable to wear on the shoulder or upper arm, making it ideal for accurate occupational noise measurements across a wide range of workplaces.

 

Workplace Noise Monitoring

The NoisePen is ideal for measuring individual noise exposure in busy workplaces where people move between tasks or operate noisy machinery. It allows Health and Safety teams to monitor employees throughout their shift without supervision, making it especially useful where it is unsafe or impractical to take measurements with a handheld sound level meter. The device is worn on the shoulder or upper arm and runs automatically once configured in our licence-free AnalyzerPlus software. After monitoring, results can be downloaded to create clear reports for workplace noise assessments.

 

Hospitality Noise & Entertainment Noise

The NoisePen Noise Dosimeter is ideal for monitoring noise exposure in venues where music and crowd noise change throughout the day. It provides reliable measurements without supervision, making it ideal for bars, nightclubs, theatres, and live events. Since it runs automatically once set up in our licence-free AnalyzerPlus software, staff can wear it comfortably during their shift without disruption. Once monitoring is complete, results can be reviewed to help protect employees and comply with workplace noise regulations.

Specifications

Accuracy
Class 2

Applicable standards
IEC 61252:1993
ANSI S1.25:1991
IEC 61000-6-1:2007(EMC)
IEC 61000-6-3:2007(EMC)

Microphone
Removable Pre-polarised Electret ½” Class 2

Measurement range
70-140dB(A)
90dB(C) to 143dB(C) Peak

Time Weightings
‘F’ (Fast), ‘S’ (Slow) or None

Frequency weightings
CH1 (Integrator): A
CH2 (Peak), C & Z

Integrators
One integrator. Set up either: UK, EU, OSHA, HC & OSHA NC, OSHA HC & ACGIH, MSHA HC & MSHA
EC or Custom

Time History data Rates
One second, one minute

Languages
English, French, German, Italian and Spanish as standard

Power/Batteries
Custom-made 1.2V Internal NiMH battery pack.
Rechargeable via USB 5V

Battery life
Over 30 hours measuring
Recharge in less than 4 hours (0% to 100%)
Weight with battery: 82gms

Size
124mm x 34mm x 28mm excl windshield

Connections
Mini-USB (supplied) to connect to PC or power supply

Operating temperature
0-40°C

Memory
Enough memory to store 20 x 8hr shifts at storage of 1s for both Peak and integrator 160hrs at 1s storage rate)

Measurement parameters
Graph of Short LAeq, LCPeak or LZPeak

Software
Pulsar AnalyzerPlus for Windows 7 and above

Warranty
12 months extendable to 7 years

Accessories
Acoustic Calibrator
Kit cases
NoisePen fixings
Mains Power Supply

Downloads

Datasheet (pdf, 182KB)
English
Datasheet (pdf, 336KB)
German
Datasheet (pdf, 135KB)
French
User Manual (pdf, 588KB)
English

Reviews (1)

1 review for NoisePen Personal Noise Dosimeter

  1. Innocent Mutambuze

    The NoisePen is very user-friendly, operating as a true plug-and-play device.

    Reviewer was offered a benefit for sharing their feedback.

Add a review

Your email address will not be published. Required fields are marked *

You may also like…

10-Year Warranty on Selected Pulsar Products

10-Year Warranty on Selected Pulsar Products

Selected products include an extended 10-year warranty when calibrated annually.

Online Training with Noise Products

Online Training with Noise Products

Access our Online Noise Awareness Course at no extra cost when you buy our noise monitoring equipment.

Licence-Free Software with Pulsar Products

Licence-Free Software with Pulsar Products

Use our software without subscriptions, recurring charges or additional licence fees.

Trusted by Organisations Worldwide

Over 50 years of supplying reliable noise and vibration measurement equipment

Pulsar Nova Customers