Warranty

7-Year Warranty

We focus on customer care, providing great support, advice and assistance.

5 stars

Rated 5 Stars

Pulsar Instruments are highly recommended and trusted by our customers.

Fast Delivery

Free UK Shipping

Free next-day despatch on all orders placed before 12 pm.

Secure Checkout

Secure Payment

Pay for your goods via our secure payment server, with a Credit or Debit card.

50 years in business

50+ Years in Business

We’re recognised and trusted noise measurement experts – Since 1969.

Acoustic Calibrators – Class 1 zoom

Hover

5d78c187c09a1514944457 zoom

Hover

5da5d999cd96f209301887 zoom

Hover

5da5d96d1e70a192874019 zoom

Hover

Acoustic Calibrators – Class 1
5d78c187c09a1514944457
5da5d999cd96f209301887
5da5d96d1e70a192874019
Full Screen

Acoustic Calibrators – Class 1

$621,60 (Ex. VAT/GST)

Pulsar Instruments’ Class 1 acoustic calibrator with EU Type Approval.

  • Quickly check the accuracy of your sound level meter, dosemeter or other instruments
  • Make sure your measurements are compliant
  • Use to field calibrate your sound level meters and noise dosemeters to 94 dB at 1kHz

$621,60 (Ex. VAT/GST)

10 in stock

  • Quickly check the accuracy of your sound level meter, dosemeter or other instruments
  • Make sure your measurements are compliant
  • Use to field calibrate your sound level meters and noise dosemeters to 94 dB at 1kHz
  • Delivery Time | 2-3 days
  • Warranty | Extended 7-year warranty
  • Calibration | 12-months
  • Software | License-free software included
  • Shipping | Worldwide

We accept the following payments:

Payments accepted

Description

Acoustic Calibrator Models 105 (Class 1) and Model 106 (Class 2) have been tested and formally EU Pattern Approved by the PTB (under certificate PTB-1.61.4034842), as meeting all of the requirements of the latest International standard, IEC 60942: 2003 (equivalent to ANSI/ASA S1.40-2006). This version of the IEC international standard is far more stringent than previous versions and so far very few manufacturers have managed to meet it. The two models are intended to field calibrate (that is set the sensitivity), of any properly approved noise meter that uses a standard measurement microphone.

To ensure your noise measurements are legally compliant with Noise Regulations you MUST field calibrate your sound level meter before and after taking your measurements; most noise-related regulations stipulate that the noise meter or noise dosemeter is calibrated before each acoustic calibration session and checked again before turning the instrument off.  In fact, noise measurements made for ‘official’ use, such as industrial health & safety or environmental monitoring, are not valid unless correct calibration procedures have been followed.

Both the Models 105 (Class 1 acoustic calibrator) and Model 106 (Class 2 acoustic calibrator) give a standardised 1kHz tone for sound level calibration (calibration level) – the frequency where all weighting networks are the same, at a pressure of 1 Pascal which is a sound level of 94 decibels. They have sensors to correct for temperature, humidity, barometric pressure and battery voltage so that they remain stable and accurate under almost any conditions where they are likely to be used.

  • The units are simple to operate and meet the requirements of the latest IEC 60942:2003 standard for Class 1 and Class 2 Calibrators
    • Model 105 sound level calibrator complies fully with Class 1 – the precision class, meeting the requirements of Class 1 sound level meters.
    • Model 106 complies fully with Class 2, meeting the requirements for the calibration of industrial Class 2 sound level meters used in almost all Health and Safety applications.
  • We have taken great care during the design process to ensure that the units are comfortable to hold, robust and easy to used, whilst performing accurately throughout a wide range of temperature, humidity and pressure conditions.
  • The calibrators are powered by an easy-to-access single 9-volt battery giving many months or even years of operation. An automatic shut-off circuit ensures power conservation should you forget to switch off the unit.

A separate Model 108 Class 2 field calibrator specifically made for use with the Pulsar NoisePen personal noise dosimeter is also available. It gives a standardised tone at 114dB. The NoisePen also accepts the Model 106.

Applications / Features

Features
  • Advanced performance ensures that both models meet or exceed IEC 60942 accuracy requirements
  • Full PTB pattern approval awarded on both models
  • Ergonomic and robust design ensures comfortable use
  • Auto-correction for temperature and barometric pressure
  • Auto switch off in normal mode and ‘permanent-on’ mode available
  • 94dB Sound Pressure Level
  • Fits ½ inch international standard microphones
  • ¼ inch adaptor available
  • Calibration certificate included
  • 12 months’ warranty extendable to 7 years
  • Acoustic Calibration of noise meters and dosemeters

Software / Accessories

Models 105 and 106

Whilst both the Model 105 and Model 106 can be ordered separately, they are most often supplied as part of a noise measurement kit. The Model 105 for a Class 1 noise measurement kit and the Model 106 for a Class 2 noise measurement kit.

Each Sound Level Calibrator is supplied with the following:
  • User manual
  • Certificate of calibration
  • Battery (9V)
  • 12 months warranty extendable to 7 years*

* To qualify for the 7-year warranty, you will need to send your Calibrator back to us annually for service and recalibration whereupon the warranty is extended for a further 12 months for up to 7 years.

Downloads

Pulsar Model 105 & 106 datasheet – ENGLISH

Download Now (PDF)


Pulsar Model 105 & 106 datasheet – FRENCH

Download Now (PDF)


Pulsar Model 105 & 106 datasheet – GERMAN

Download Now (PDF)


Ptb certificate for acoustic calibrator

Download Now (PDF)


Pulsar Model 105 & 106 datasheet – ITALIAN

Download Now (PDF)

Reviews

There are no reviews yet.

Only logged in customers who have purchased this product may leave a review.

Related Products

Clients trust in us to deliver quality and superior service

Pulsar Instruments are highly-recommended and trusted by our customers.

Latest news stories

Read our latest news articles here…

Introducing the Pulsar Nova Pro: The Ultimate Environmental Noise Analyser
Introducing the Pulsar Nova Pro: The Ultimate Environmental Noise Analyser

19th Jun 2024

Pulsar Instruments is proud to announce the launch of our latest innovation in noise measurement technology, the Pulsar Nova Pro Environmental Noise Analyser. This state-of-the-art…

Read full story

Festive Opening Hours 2023
Festive Opening Hours 2023

06th Dec 2023

We can’t believe that it’s already December! The team here at Pulsar Instruments would like to thank you for your continued support throughout 2023. We…

Read full story

Pulsar Instruments Announces Two New Distributors in the Middle East
Pulsar Instruments Announces Two New Distributors in the Middle East

30th Oct 2023

As part of Pulsar Instruments’ ongoing commitment to expanding in the Middle East, we are excited to announce partnerships with two new regional distributors. After…

Read full story

Read all articles about Pulsar Instruments and the latest information and guidelines for noise measurement and sound control in your industry…

All news stories

We’re the noise measurement equipment
Experts
with over 50 years experience

7-Year Warranty
7-Year Warranty

We focus on customer care, providing great support, advice and assistance.

Rated 5 Stars
Rated 5 Stars

Pulsar Instruments are highly recommended and trusted by our customers.

Free UK Shipping
Free UK Shipping

Free next-day despatch on all orders placed before 12 pm.

Don’t miss out! Subscribe now…

Sign up to our newsletter to stay up-to-date with…

The latest news about Pulsar Instruments products, training days and company updates.

The latest guidelines and suggested recommendations for noise measurement and sound control.

Exclusive offers, discounts and promotions delivered directly to your inbox.


  • This field is for validation purposes and should be left unchanged.